Consulting
Design management systems and improve the processes your teams use every day.
Explore consulting
Discuss your project ↗
Design management systems and improve the processes your teams use every day.
Explore consulting →
Assess supplier, production and management system controls using evidence from actual work.
Explore auditing →
Build practical skills in management systems, internal auditing and team development.
Explore training →Use the Sakhi Knowledge Centre to plan an audit, compare management systems or build an evidence checklist.
Explore the Knowledge CentreSee Sakhi training and workshops on management systems, supplier quality, sustainability and team development.
Explore Sakhi’s articles on consulting, auditing and training. For step-by-step guides and worked examples, visit the Knowledge Centre.
Prepare for NABL accreditation by proving technical competence for each test or calibration in the proposed ISO/IEC 17025 scope. Trace a released result to its method, authorised person, equipment status, original observations, quality controls and applicable decision rule.

For each proposed entry, capture the method and version, measurable parameter, product or matrix, applicable range or capability, and responsible technical staff. Tie these to verification or validation evidence, equipment and traceability, and the planned external comparison or proficiency testing (PT). Check the latest relevant NABL documents for the type of laboratory and scheme. Start with work the laboratory can demonstrate consistently.
Verification checks whether the laboratory can achieve the required performance when it correctly implements an established method. Validation considers whether the method is fit for the intended use in cases such as a laboratory-developed or modified method. Set the acceptance criteria before collecting evidence. Check for changes to sample matrix, range, software, equipment or personnel that could affect performance, and decide what to review again.
A decision rule sets how measurement uncertainty is considered when reporting whether a result conforms to a specification. Document the rule and agree it with the customer when required, unless the relevant specification or standard already prescribes it. Confirm the limit, direction of conformity, units and scope of the statement. In technical review, ask whether another authorised reviewer can reach the same reporting decision from the same results.
An illustrative dimensional test has an upper limit of 10.00 mm. The measured result is 9.98 mm with an expanded uncertainty of 0.05 mm. The upper end of that interval is 10.03 mm. If the agreed guard-band rule accepts only when measured value plus expanded uncertainty is at or below the limit, this result fails to meet the acceptance criterion. The report should follow the agreed rule, including how it describes borderline or indeterminate outcomes.
An ISO/IEC 17025 readiness exercise can start with a single issued result and trace the sample ID, method version, instrument, raw data, calculation and authorised review. Ask a second reviewer to reproduce the reported value from the retained records.
Record the report number and sample ID. Retrieve the raw file and approved calculation worksheet or software configuration used on the day the result was generated.
Review the analyst's authorisation for the method at the test date, along with the instrument status and relevant quality-control results for that run.
If the final number was revised, verify who authorised the change, why it was needed and how the current issue is linked to the earlier issue. Retain the record trail for technical review.
| Focus | What to check | Evidence or decision |
|---|---|---|
| Scope | What to checkMethod, matrix or range and location | Evidence or decisionApproved scope entry and method evidence |
| Technical result | What to checkRaw readings, equipment and calculations | Evidence or decisionTraceable certificate or record, control results, reviewer check |
| Conformity statement | What to checkApplicable requirement and decision rule | Evidence or decisionCustomer agreement when needed and report sign-off |
Accreditation applies to the published scope. Check the test or calibration, method, location and relevant range or capability against that scope.
Treat it as one evidence point. Review relevance, PT coverage, internal quality-control trends and corrective action where performance was unsatisfactory.
Recalculate a representative result independently using approved inputs, units and rounding. Record which worksheet version was used and who reviewed the check.
Share a proposed scope and an example report. Sakhi can help review method, competence and technical evidence for readiness.
2026 © www.isoconsultants.in. All Right Reserved. | Website Design Company in India Maitrix Infotech